JHOTA 5KW PV 145V Input AC 220/230V OutPut Match 48V battery Pure Sine Wave Parallel Inverter Optional Wifi Module
Support 1-6 pcs parallel/split phases
  
 Quick Details:
1. MOQ: 5
 2. Best choice for home energy storage
 3. Warrenty: 3 Years
 4. AC Output Voltage Waveform: Pure Sine Wave
 5. Rated AC Output Power: 5000(4350/4500/4750/5000VA)
 6. Peak Power: 10000VA
Description:
JHOTA's Parallel Inverter is a low frequency pure sine wave inverter and MPPT solar charge controller.
One of the highest performing off-grid inverters on the market. Ideal for off-grid backup power and self-consumption applications.
An all-in-one unit that provides power from a solar array, 48v battery pack or generator/utility.
 Specification:
| Battery Input | |
| Battery type | Sealed, FLood, GEL, LFP, Ternary | 
| Rated Battery Input Voltage | 48V (Minimum Startup Voltage 44V) | 
| Hybrid Charging Maximum Charging Current | 140A | 
| Battery Voltage Range | 40Vdc~60Vdc ± 0.6Vdc(Undervoltage Warning/Shutdown Voltage/Overvoltage Warning/Overvoltage Recovery...) | 
| Solar Input | |
| Maximum PV Open-circuit Voltage | 145Vdc | 
| PV Working Voltage Range | 60-145Vdc | 
| MPPT Voltage Range | 60-115Vdc | 
| Maximum PV Input Current | 50A | 
| Maximum PV Input Power | 4400W | 
| Maximum PV Charging Current | 80A | 
| AC Input (generator/grid) | |
| Mains Maximum Charging Current | 60A | 
| Rated Input Voltage | 220/230Vac | 
| Input Voltage Range | UPS Mains Mode: (170Vac~280Vac) ± 2% APL GeneratorMode:(90Vac~280Vac) ± 2% | 
| Frequency | 50Hz / 60Hz (Automatic Detection) | 
| Mains Charging Efficiency | >95% | 
| Switch Time (bypass andinverter) | 10ms (Typical Value) | 
| Maximum Bypass Overload Current | 40A | 
| AC Output | |
| Output Voltage Waveform | Pure Sine Wave | 
| Rated Output Voltage | 230 (200/208/220/240Vac) | 
| Rated Output Power | 5000 (4350/4500/4750/5000VA) | 
| Rated Output Power | 5000 (4350/4500/4750/5000W) | 
| Peak Power | 10000VA | 
| On-load Motor Capacity | 4HP | 
| Output Frequency Range(Hz) | 50Hz ± 0.3Hz / 60Hz ± 0.3Hz | 
| Maximum Efficiency | >92% | 
| No-load Loss | Non Energy-saving Mode: ≤50W Energy-saving Mode: ≤25W (Manual Setup) | 
| General | |
| Number of parallel/split phases | 1-6 PCS | 
| Certificate | CE(IEC 62109-1) | 
| EMC Certification Level | EN61000,C2 | 
| Working Temperature Range | -15°C ~ 55°C | 
| Storage Temperature Range | -25°C ~ 60°C | 
| Humidity Range | 5% to 95% (Conformal Coating Protection) | 
| Dimensions | 426mm*322mm*124mm | 
| Weight | 10.8 KG | 
Installation and Wiring:
 1. Confirm the installation position and heat dissipation space
 2. Confirm the installation position of all-in-one machine
 3. Such as wall surface; to install the all-in-one machine, guarantee there is sufficient air flowing
 through the cooling fins of all-in-one machine.
 4. At least reserve 200mm space at the left and right air outlets of
 the all-in-one machine to guarantee heat loss through natural convection.
 5. Refer to the overall installation schematic above.
 6. Never install the all-in-one machine and lead-acid liquid battery into a
 same sealed space or in a sealed place with probable accumulation of battery gas.
  
 Product image:
 